Home >> Product >> Online Transformerless UPS >> 3W310-120K
Key Point
• Range: 10〇-40〇k
• Rated Voltage: 380VAC
• Rated Frequency: 50Hz/60Hz
• Output PF: 0.9
Key Feature
Efficiency and Reliable
• 0.9 output PF is to ensure that the load ability will be better
• UPS can be used in parallel, the maximum 6 pcs parallel to reach the expand demand
• Adopt advanced high frequency technology IGBT, THDi is less than 3%, input power factor is larger than 0.99, pollution to grid is almost zero
• UPS start-up has delay function, cut down the impact to frontal load device
• Intelligent battery management system, improve the performance and life time to batteries with multiple charging methods
• The design of high efficiency makes UPS efficiency is more than 98%
• Chinese and English display can be selected from interface
Model # | 3W3EX100K | 3W3EX120K | 3W3EX160K | 3W3EX200K | 3W3EX300K | 3W3EX400K |
Capacity | 100KVA | 120KVA | 160KVA | 200KVA | 300KVA | 400KVA |
INPUT INDICATORS | ||||||
Rated voltage | 380Vac | |||||
Range of input voltage | "-45% ~ +25%; ± 25% work with full load,- 25% — 45% work by reducing capacity,- 45% work with 70% load" | |||||
Frequency | 45 ~ 65Hz | |||||
Input way | Three phase Four wire | |||||
Power factor | 0.99 | |||||
THDi | ^3% | |||||
OUTPUT INDICATORS | ||||||
Output PF | 0.9 | |||||
Output voltage | 380Vac + 1% | |||||
Voltage THD | Linear Load < 1 % ; Non-Linear Load < 2% | |||||
Synchronous frequency accuracy | <0.001% | |||||
Range of adjustable frequency | 50Hz ± 0.5 ~ ± 2 can be adjustable | |||||
Overload time | 110%=5h; 125=10min; 150=1min; >250%=200ms | |||||
Phase discrete degree | 120° ± 1。( 100% Unbalanced load ) | |||||
Three-phase voltage unbalance degree | ± 1 % ( balanced load ); ± 1.5% ( 100% Unbalanced load ) | |||||
Crest factor | 3:1 | |||||
Bypass working voltage | adjustable from + 5% to + 25% | |||||
UPS efficiency | ^98% | |||||
Transfer time | Oms | |||||
Dynamic response transient range | Load changes from 0 〜100% less-than ± 2% | |||||
Dy门amic「csponsG transient recovery time | 10ms | |||||
Overload capacity of static switch | 20 times current ( 100ms ) | |||||
Panel display mode | LCD+LED | |||||
Redundant parallel technology | Directly do parallel with parallel board | |||||
WORKING ENVIORMENT | ||||||
Range of operating temperature | -25t 〜701 | |||||
Storage temperature | -251 〜7CTC | |||||
Continuous operating temperature | Top 40 °C, 8 hours | |||||
Relative humidity | 0 〜95%,no condensing | |||||
Maximum operation height | 3000 Meters | |||||
Noise (1m) | 52dB | |||||
OTHERS | ||||||
The perturbation resistance meet | ENeiOOO-4-2,3,4,6,8,11 Level III .EN61000-4-5 Level IV.EN50091-1-1-1.A | |||||
MTBF (System) | More than 250000 hours | |||||
MTTR (Board level maintenance) | 10min | |||||
Surge | support voltage pulse 10/700us support current pulse 8/20us, 20KA | |||||
Protection level | IP21(IP31 optional) | |||||
Dimension (D x W x H) (mm) | 950*600*1600 | 950*800*2000 | 950*1200*2000 | |||
Weight (KG) | 340 | 440 | 450 | 790 | 870 |